Monday, October 18, 2010

Fix the #1 Most Common Refrigerator Problem

Fix the #1 Most Common Refrigerator Problem "Defrost Cycle"


Troubleshooting Refrigerator Problems

<object classid="clsid:d27cdb6e-ae6d-11cf-96b8-444553540000" codebase="http://fpdownload.macromedia.com/pub/shockwave/cabs/flash/swflash.cab#version=8,0,0,0" type="application/x-shockwave-flash" width="400px" height="325px">
<param name="movie" value="http://www.linkedtube.com/static/flash/player.swf?sum=It%27s%20Easy%20When%20You%20Know%20How!&btn=ApplianceAssistant.com&txt=Appliance%20Repair%20Help&vis=hover&url=http%3A%2F%2Fwww.applianceassistant.com.com&vid=TnRKj7_BtNw"/>
<param name="quality" value="high" />
<param name="menu" value="false" />
LinkedTube
</object>
refrigerator

A refrigerator doesn't actually create cold. It removes heat.  Cold is the absence of heat, and the complete absence of heat is considered absolute zero, which is −459.67°F −273.15°C .

You may wonder where the "cold" came from, here is a little more physics. As the refrigerant moves from the very small capillary tube into the larger tubing of the evaporator the pressure of the refrigerant is greatly reduced causing it to boil at a lower temperature, greatly increasing its ability to absorb the warm air within the freezer compartment.

Your refrigerator has a compressor which is part of a sealed system of tubing that contains a special gas (the refrigerant). The compressor pumps the refrigerant through a very thin tube on its way to the inside of the freezer compartment. As the refrigerant exits this thin tube it enters a larger one. As the pressure of the gas drops, it’s ability to absorb heat increases.

AppliancePartsPros.com, Inc.

UNDERSTANDING REFRIGERATION :
REFRIGERATION COMPONENTS and TESTING PROCEDURES PDF

Inside the freezer, a fan circulates air over the cool tubing and the refrigerant absorbs the heat from the freezer's warmer air.  Just like wind moving from a high-pressure zone into a low-pressure zone to equalize, heat will move toward cooler areas to try to equalize.  Equality cannot be achieved because the now warm gas continues through the system to the condenser. As the heated gas flows through the condenser coils on the back or under the refrigerator, the heat within the gas leaves in favor of the cooler air in the room, and the cycle starts again. If you prefer to just think of the fan blowing cold air into the appliance that's fine; but technically, the heat is being pumped out rather than cold being pumped in.

The cold air that is generated in the freezer passes through vents (the air diffuser) to the refrigerator compartment. A thermostat or cold control in the refrigerator activates the compressor whenever the temperature rises above the set point.  In some newer models there is a separate cooling coil for the freezer and the refrigerator and thus two temperature controls.

Troubleshooting Refrigerator Problems

As the air in the refrigerator cools, the water in the air (humidity) condenses. Water that condenses in the freezer will freeze and become frost. Most modern refrigerators have an automatic defrost heater in the freezer, which cycles on from time to time to prevent the build up of frost. The defrost system is simply a heating element that is controlled by a defrost timer and a thermostat. The water from the melted frost drains out of the refrigerator into a pan beneath the refrigerator near the hot condenser coils or compressor and evaporates.

A door switch closes a circuit when the door is opened and turns on the interior light. When the door is open some refrigerators will disable certain components such as the fan, defrost heater, icemaker, or ice and water dispensing systems.

Refrigerators and freezers don't cool efficiently when operated at temperatures below, roughly, 45 degrees (F). The first reason is that the outside temperature may get so low that the thermostat inside the refrigerator never gets warm enough to activate the compressor, so the freezer warms up to the outside temperature. Another problem is that if it gets too cold, the refrigerant pressure becomes too low to generate the necessary cold, so the freezer only chills down to the outside temperature. This can be a common issue when operating a refrigerator in the garage or other unheated space during cold weather.

For more information on the individual systems of a refrigerator visit the troubleshooting common problems or Refrigerator Physics pages.

AppliancePartsPros.com, Inc.

2 comments:

  1. Thanks for your post. I’ve been thinking about writing a very comparable post over the last couple of weeks, I’ll probably keep it short and sweet and link to this instead if thats cool. Thanks. Sub-Zero, Viking REFRIGERATOR REPAIR IN CHINO

    ReplyDelete